Forced Draft (SVC Series) – Evaporative Condensers

Forced draft evaporative condensers (SVC series) is the design of the blast, centrifugal fan mounted on the bottom of the device integrated with the water tray, the use of the belt drive system case of this series of evaporative cold noise is less, suitable for indoor installation of the occasion. This series of evaporative cooling can also be container transport. SVC Series evaporative cooling is also very easy to maintain, both sides of the fan shell plate can be removed, it is easy to access the entire belt drive system.

Forced draft evaporative condensers (VC/SVC series) are executed on principle of forced air flow. With 10 different models according to capacity covering an extremely wide range of application according to required capacities in different ambient conditions. Condensers are generally used for R717(ammonia) but also suitable for refrigerants like R404, R134a, R507a etc.
Model Heat Rejection Capacity (kW) Model Heat Rejection Capacity (kW)
SVC-450 405.0 SVC-1150 1035.0
SVC-480 432.0 SVC-1195 1075.5
SVC-540 486.0 SVC-1410 1269.0
SVC-600 540.0 SVC-1570 1413.0
SVC-650 585.0 SVC-1850 1665.0
SVC-720 648.0 SVC-1920 1728.0
SVC-800 720.0 SVC-2050 1845.0
SVC-900 810.0 SVC-2450 2205.0
SVC-950 855.0 SVC-2950 2655.0
SVC-1080 972.0 SVC-3250 2925.0

Heat Rejection Capacity Factor:

Correction Factor for Refrigerant R717:

Condensing Temperature (°C) Air Inlet Wet Bulb Temperature (°C)
10 12 14 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
301.071.151.251.381.471.571.691.832.002.232.502.863.36–––––
320.941.011.091.191.261.321.401.491.601.741.902.112.36–––––
340.850.900.971.041.091.141.201.261.261.431.431.661.812.022.31–––
350.800.850.910.971.021.061.111.151.151.291.291.461.561.711.892.132.412.77
360.770.810.860.920.961.001.041.071.071.191.191.341.431.561.711.902.142.43
380.700.740.780.820.850.880.900.930.931.011.011.111.181.261.351.471.621.78
400.650.670.700.730.760.780.800.830.830.890.890.971.021.081.141.221.321.44
420.590.620.640.670.680.700.720.740.740.800.800.860.890.940.941.041.111.19
440.540.560.590.610.620.630.650.660.660.700.730.750.820.820.820.890.920.97

Correction Factor for Refrigerant R404A, R22 & R134A:

Condensing Temperature (°C) Air Inlet Wet Bulb Temperature (°C)
10 12 14 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
30 0.951.031.121.231.311.401.511.631.791.992.242.563.00–––––
32 0.840.900.971.061.121.181.251.321.431.551.701.882.11–––––
34 0.760.810.860.930.981.021.071.121.191.281.381.481.611.802.06–––
35 0.710.760.810.870.910.950.991.031.081.151.231.311.391.531.691.902.152.47
36 0.690.730.770.820.860.890.920.961.011.071.131.201.281.391.531.701.912.17
38 0.630.660.690.730.760.780.810.830.860.900.940.991.051.121.211.311.441.59
40 0.580.600.620.650.670.700.720.740.760.800.830.870.911.021.021.091.181.29
42 0.530.550.570.600.610.630.640.660.680.710.740.760.801.880.880.930.991.06
44 0.490.500.520.540.560.580.580.590.610.630.650.670.700.760.760.790.830.86

Why Choose DR Snowkey Evaporative Condensers (Induced Draft)

  • Nitrogen charged coils
  • Safety ladder mounted with condenser for access of condenser top
  • Integrated PVC drift eliminators for longer life
  • Low level switch and high-level float valve
  • Hinged access door for easy access, maintenance and cleaning of condenser inside
  • Directly examinable and repairable water spray system
  • Wide spaced non-clogging air inlet louvers
  • PVC water distribution pan as integral part of water spray and distribution system
  • Easy access to fan drive system and condensing coils
  • Sloped water basin floor for ease of cleaning
  • All steel panels and structure elements with high anti-corrosive galvanized steel
  • All cut edges with zinc-rich primer applied before assembly
  • Condensing coils designed as per ASME standards for 20 Bar pressure and tested at 25 Bar
  • Coil design with slope for easy drain and movement of condensed liquid
  • Coil assembly and steel housing assembly is Hot Dip Galvanized

Use Case

  • Food Processing Industry
  • Beverage, Juice & Brewery Industry
  • Bakery & Confessionary Industry
  • Dairy & Ice-cream Industry
  • Fish, Meat, Poultry Processing
  • Cold Stores & CA Stores
  • Ice Blocks & Ice Manufacturing

Interested?

Get a Quote

Forced Draft (SVC Series) – Evaporative Condensers

Forced draft evaporative condensers (SVC series) is the design of the blast, centrifugal fan mounted on the bottom of the device integrated with the water tray, the use of the belt drive system case of this series of evaporative cold noise is less, suitable for indoor installation of the occasion. This series of evaporative cooling can also be container transport. SVC Series evaporative cooling is also very easy to maintain, both sides of the fan shell plate can be removed, it is easy to access the entire belt drive system.

Interested?

Get a Quote

Forced draft evaporative condensers (VC/SVC series) are executed on principle of forced air flow. With 10 different models according to capacity covering an extremely wide range of application according to required capacities in different ambient conditions. Condensers are generally used for R717(ammonia) but also suitable for refrigerants like R404, R134a, R507a etc.
Model Heat Rejection Capacity (kW) Model Heat Rejection Capacity (kW)
SVC-450 405.0 SVC-1150 1035.0
SVC-480 432.0 SVC-1195 1075.5
SVC-540 486.0 SVC-1410 1269.0
SVC-600 540.0 SVC-1570 1413.0
SVC-650 585.0 SVC-1850 1665.0
SVC-720 648.0 SVC-1920 1728.0
SVC-800 720.0 SVC-2050 1845.0
SVC-900 810.0 SVC-2450 2205.0
SVC-950 855.0 SVC-2950 2655.0
SVC-1080 972.0 SVC-3250 2925.0

Heat Rejection Capacity Factor:

Correction Factor for Refrigerant R717:

Condensing Temperature (°C) Air Inlet Wet Bulb Temperature (°C)
10 12 14 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
301.071.151.251.381.471.571.691.832.002.232.502.863.36–––––
320.941.011.091.191.261.321.401.491.601.741.902.112.36–––––
340.850.900.971.041.091.141.201.261.261.431.431.661.812.022.31–––
350.800.850.910.971.021.061.111.151.151.291.291.461.561.711.892.132.412.77
360.770.810.860.920.961.001.041.071.071.191.191.341.431.561.711.902.142.43
380.700.740.780.820.850.880.900.930.931.011.011.111.181.261.351.471.621.78
400.650.670.700.730.760.780.800.830.830.890.890.971.021.081.141.221.321.44
420.590.620.640.670.680.700.720.740.740.800.800.860.890.940.941.041.111.19
440.540.560.590.610.620.630.650.660.660.700.730.750.820.820.820.890.920.97

Correction Factor for Refrigerant R404A, R22 & R134A:

Condensing Temperature (°C) Air Inlet Wet Bulb Temperature (°C)
10 12 14 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
30 0.951.031.121.231.311.401.511.631.791.992.242.563.00–––––
32 0.840.900.971.061.121.181.251.321.431.551.701.882.11–––––
34 0.760.810.860.930.981.021.071.121.191.281.381.481.611.802.06–––
35 0.710.760.810.870.910.950.991.031.081.151.231.311.391.531.691.902.152.47
36 0.690.730.770.820.860.890.920.961.011.071.131.201.281.391.531.701.912.17
38 0.630.660.690.730.760.780.810.830.860.900.940.991.051.121.211.311.441.59
40 0.580.600.620.650.670.700.720.740.760.800.830.870.911.021.021.091.181.29
42 0.530.550.570.600.610.630.640.660.680.710.740.760.801.880.880.930.991.06
44 0.490.500.520.540.560.580.580.590.610.630.650.670.700.760.760.790.830.86

Why Choose DR Snowkey Evaporative Condensers (Induced Draft)

  • Nitrogen charged coils
  • Safety ladder mounted with condenser for access of condenser top
  • Integrated PVC drift eliminators for longer life
  • Low level switch and high-level float valve
  • Hinged access door for easy access, maintenance and cleaning of condenser inside
  • Directly examinable and repairable water spray system
  • Wide spaced non-clogging air inlet louvers
  • PVC water distribution pan as integral part of water spray and distribution system
  • Easy access to fan drive system and condensing coils
  • Sloped water basin floor for ease of cleaning
  • All steel panels and structure elements with high anti-corrosive galvanized steel
  • All cut edges with zinc-rich primer applied before assembly
  • Condensing coils designed as per ASME standards for 20 Bar pressure and tested at 25 Bar
  • Coil design with slope for easy drain and movement of condensed liquid
  • Coil assembly and steel housing assembly is Hot Dip Galvanized

Download Product Documents

Screw Compressors - Brochure

PDF 2.40MB

Heating and Refrigeration Products & Service

PDF 1.45MB

Product Specifications DEC Screw Compressor

PDF 4.12MB